Flow rate - petrol: | standard 40 L/min high 80 L/min ultra high 130 L/min to 150 L/min |
- CNG: | standard 30 kg/min increased 70 kg/min |
Accuracy of dispensing - petrol: - CNG: | ± 0.25% (at min. delivery 2 L) ± 1.50% (at min. delivery 2 kg) |
Maximum pressure - petrol: - CNG: | 0.25 MPa 30.0 MPa |
Electric motors: | thrее-phase, 3x400V/50Hz, 0.75kW, 1395 rpm |
Counter power supply: | 230V +10% -15%, 50Hz max.300VA |
Power supply of the switching elements: | +24VDC |
Operating temperature: | -20°C ~ +40°C |